TANK WEIGHING SYSTEMS |
|
- Batching
- Vessel Weighing
- Reactor Weighing
- Hopper Weighing
- Flow monitoring
- Loss / Grin-in-weight
|
|
|
Specifications |
|
|
|
Model |
Capacity |
Accuracy |
| TN 5 |
5 Ton |
± 0.1% |
| TN 10 |
10 Ton |
| TN 15 |
15 Ton |
| TN 20 |
20 Ton |
| TN 30 |
30 Ton |
|
TN 50 |
50 Ton |
| TN 150 |
150 Ton |
| TN 300 |
300 Ton |
|
Weighing Range |
100kg to 300 tones |
| Load sensor |
Precision
Strain guage loadcell |
| System
Accuracy |
+/- 0.1% |
| Zero
adjustment |
Adjustable
by soft touch keyped |
| indicator |
5 digit
13mm/25mm LED display |
| Power
supply |
230V, 50HZ,
10% (optional: 100V, 50HZ, 10%) |
|
Temperature range |
5°C
to 50°C |
Encloser
(Electronics)
(Loadcell) |
1 IP-55 for
field mounted
2 IP-54 for control room housing
Hermetically sealed with inert gas filling |
|
|
|
|
Standard Features |
- No moving parts.
- The most reliable strain gauge loadcells.
- High accuracy.
- Practically no maintenance.
- Standard electronics will have 4 relay outputs 4-20mA isolated
current.
- Absolutely cost effective
- Expandable control output to use as batch controller.
|
|
|
|
PROCESS WEIGHING |
| Liquid
Batching |
Power/Granule
Batching |
 |
 |
|
|
|
|
Strain gauge instrumentations amplifier |
- Analog O/P : 4-20 mA or 0-10 VDC.
- LED bar O/P - Level indicator.
- AC or DC supply.
- DIN rail mounting.
|
|
FW-1000 Series |
- RS422/485 communication port.
- isolated Analog O/P : 4-20 mA or 0-10 VDC (Optional).
- 2 nos. Relays potential free contacts for set point or refilling
(Optional).
- Available in Weatherproof IP-65 or Flameproof Execution certified by
CMRI & CCE up to Gas group IIB.
|
|
Batching Controller |
- 250/1000 conversations/sec. ADC speed for precise controlled
accuracy.
- Free programming software.
- Customized printing software.
- 4 Communications ports.
- Profibus connectivity (Optional).
- Panel mounting with Ip66 front.
- Flow rate control through inbuilt IPD.
- Batching with 32 programs & 256 recipes.
- Upto 178 I/Os and 8 nos. 4-20 mA O/P.
|
|
Strain gauge instrumentations amplifier |
- 3 sets of Displays for simultaneous indication
of Nett Weight. Loss/Gain in weight , Flow Rate.
- 6 assignable parameters for 2 relays (Expandable up to 6 relays)
- Isolated 2 Nos. -4-20 mA or 0-10 V O/P (Configurable)
- Weatherproof / Flameproof execution
|
|
Load cells |
- Nickel Plated Alloy Steel / Stainless Steel construction
- Ip67 / Ip68 / Hermetically sealed environment protection.
- Hazardous area approved to Eex la I/C T6
- High quality load cells with integrated approvals.
|
|
Mounting Assemblies |
- Internal arrangement for load cell replacement
- Built in safety against vessel fitting and built forces
- Allows vessels expansion and contractions which occurs due to
thermal effects.
- Available in 'Lug mount' and 'Ground mount version'.
|